Optics that stay clear, durably treated
Permanent anti-fog treatment, anti-reflective coating adhesion and precision cleaning for lenses and glasses.
The surface challenge
A lens that fogs up or an anti-reflective coating that peels away is an optic that no longer does its job. Fog comes from condensation the surface cannot manage; peeling, from insufficient grip.
Plasma can both activate the surface to fix a coating in place and deposit a durable functional anti-fog layer, where sprays last only a few hours.
What plasma changes
| Indicator | Before | After plasma | Method |
|---|---|---|---|
| Surface energy — glass | < 35 mN/m when soiled | > 70 mN/m | Test inks |
| Contact angle — glass | ≈ 85° | < 5° | Goniometer |
| Contact angle (water) | 90 to 105° (polyolefins) | 35 to 70° depending on exposure | Goniometer, sessile drop |
| Effect retention | — | near-logarithmic decay; still hydrophilic at 7 days | Controlled ageing |
| Pass speed | — | 6 to 120 m/min per source | Configuration to be validated |
Documented order-of-magnitude figures, not our own measurements: pre-treatment values come from the Accu Dyne Test reference tables, post-treatment values from the atmospheric plasma literature. They place the process — they still depend on the substrate, its geometry and the line speed. A trial on your own part gives you your own numbers. Have my material measured.
What plasma changes
-
01
Permanent anti-fog
An optic that stays transparent, with no reapplication.
-
02
Anti-reflective adhesion
Fix optical layers durably in place.
-
03
Surface cleaning
Prepare glass before deposition without scratching it.
-
04
Controlled wettability
Control the spreading of liquid coatings.
From your sample to your line
-
01
Characterisation
You send us a sample. We measure its starting surface energy and identify what is blocking adhesion: contamination, release agent, non-polar polymer.
-
02
Parameter trial
We vary power, pass speed, nozzle-to-substrate distance and gas until the target effect is reached, and record the parameters that got us there.
-
03
Validation
We check the result with the test that matters to you — adhesion, sealing, wetting — and document how long the effect holds on your material.
-
04
Integration
At the station, before coating or bonding, under controlled atmosphere. The sizing constraint is cleanliness, not throughput.
What plasma actually does to a surface. The detailed comparison.
What plasma does, in detail
The right equipment for this sector
-
Thin-film deposition station
1-to-300 nm thin films: anti-fog, hydrophobic, tie layer.
View the family -
Surface-discharge plasma source
Fine, uniform cleaning of an optical surface before coating.
View the family -
Precision Plasma Jet
For small parts and edge-bounded zones.
View the family
The final choice is made on your part and your cadence, not from a catalogue. All equipment, sorted by the problem it solves.
Frequently treated materials
This list is indicative. The vast majority of polymers, metals, glasses and composites can be treated with DBD plasma. The best way to confirm your case is to send us a description of your part and your objective. For the hardware, see the plasma equipment sorted by the problem it solves.
What we get asked — Optics
How long does the treatment effect last?
Activation is not permanent: surface energy decays after treatment, faster on mobile polymers and in warm storage. That is why plasma is placed immediately before the step it serves — printing, bonding, sealing. The decay rate is measurable, and we document it on your material during the trial.
Does plasma replace corona treatment?
Both raise surface energy, but not under the same conditions. Corona suits flat film running over a roller. Atmospheric DBD plasma also treats three-dimensional geometries, hollow parts and non-conductive surfaces, with a uniformity that does not depend on holding a constant air gap. On your part, the answer is settled by comparison, not by principle.
Does the treatment change the part's appearance or dimensions?
No. Plasma acts on the first few nanometres of the surface: mass, dimensions and bulk mechanical properties are unchanged. On heat-sensitive substrates, parameters are adjusted to avoid any marking, and that is one of the things checked at the validation stage.
Are chemicals or a drying step required?
No. The treatment runs on electricity and process gas, with no primer, no solvent and no drying time. That is what lets it sit inside a line without lengthening the cycle, and what removes a hazardous-goods handling station.
Can it be retrofitted to an existing line?
That is the most common case. The treatment installs inline, at production speed. Three things need checking: the space available at the useful point, the electrical and gas connections, and extraction. Those three are what the integration stage covers.
Does treatment leave visible marks on an optical surface?
Correctly set, no — the opposite, in fact: plasma removes the organic residues that cause haloing. The risk exists if power is too high or the pass too slow on a sensitive substrate. That is what the parameter trial is for: we find the window where the effect is achieved without marking, and we document it.
The selection guide
Atmospheric or vacuum? The question comes up on every project, and it is settled on three concrete criteria — not on a preference for one process.
- Both architectures, what each one can do and what it costs
- Three deciding criteria: part geometry, robotic integration, cycle time
- A grid to fill in so you can defend the choice to an investment committee
Guide being written — leave your email and you will get it on release.
In the meantime, the article comparing both architectures : The detailed comparison.
Related sectors
-
Medical
The same surface demand, on regulated devices.
-
Cosmetics
Bottles and labels, seen through decoration.
-
Biotechnology
The same substrates, but the goal is cell attachment.
What you send, what you get back
- You send
- [x] samples of your part or film, [x] minimum size.
- You receive
- surface energy values before and after, one treated sample, and a written record of the parameters used.
- Turnaround
- first reply within 48 hours, trial report within [x] business days.
- Cost
- [x]
Send a description of your part and your goal. Answer within 48 hours.
Three fields, and we get back to you
A clear view, durably.
48 hours to find out what plasma can do for your surfaces. No commitment, just clear answers from an expert.
Response within 48 hours. No commitment. A technical discussion with an expert.